What remains beneath the room?
We establish whether the floor is solid, screeded, suspended timber, retained boards or a combination—and whether access and insulation are adequate.

Different floors. One properly designed heating system.
PEP designs, supplies and installs complete wet and electric underfloor heating systems for Maida Vale mansion flats, period homes, lower-ground properties and residential refurbishments. From the first floor-level calculation to the manifold, controls, testing and commissioning, the installation is planned as one complete heating system.
A Maida Vale refurbishment can bring several very different floor constructions into one project: a retained solid floor, suspended timber rooms, a rebuilt lower-ground level and tiled bathrooms. Each needs its own installation answer.
PEP starts with the building rather than a generic kit. We review floor build-up, heat loss, active floor area, intended finishes, door and stair thresholds, plant space, controls and access before specifying the system.
The result is a coordinated design that protects room proportions and original details while giving the completed heating system the output and control the property requires.
The design must work at thresholds, stairs, skirtings, kitchens and the junctions between retained and rebuilt floors.
We establish whether the floor is solid, screeded, suspended timber, retained boards or a combination—and whether access and insulation are adequate.
Room demand, usable heated area, pipe spacing, floor finish and operating temperature are reviewed before UFH is treated as the principal emitter.
Preparation, panels, pipes, acoustic layers, decoupling, adhesives and finish are included in the calculation—not only the headline panel thickness.
Manifold position, routes, boiler or heat-pump compatibility, thermostats, actuators, power supplies and service access are coordinated together.
The right method delivers the required output without creating avoidable problems at doors, stairs, skirtings or finished-floor junctions.

Where the existing structural floor is sound, a low-profile water-based system can provide a responsive retrofit route without excavating the complete floor. Preparation, panel, decoupling, adhesive and finish are included in the level calculation.

Where an extension, basement or rebuilt floor provides sufficient depth, pipework can be fixed over insulation and incorporated into a new screed. Insulation, spacing, movement details and screed specification are coordinated as one assembly.

Heat spreader plates, supported pipe runs and insulation can form an efficient system beneath retained boards. Joist direction, pipe turns, notching restrictions and future access are resolved before the floor is closed.

Electric mats or loose cable can provide targeted comfort in bathrooms, en suites and compact tiled rooms. Fixed furniture, wet zones, sensor position, thermostat, electrical protection and staged test results are documented before covering.

PEP works with Wunda Group to provide correctly matched underfloor heating packages at highly competitive project prices. Panels and pipework are only one part of the finished system.
Manifolds, actuators, wiring centres, thermostats, pumps, blending controls, sensors and heat-source connections must work together. We review the plans and floor constructions before ordering.
Where several floor constructions meet, the schedule records which system serves each room, creating one coordinated basis for the installer, main contractor and client.
The boiler or heat pump, pumps, mixing controls, manifold and room zones must be designed as one system. A floor circuit cannot perform correctly if the available flow temperature, hydraulic arrangement or controls are unsuitable.
Where radiators remain elsewhere in the property, their different temperatures and response times are addressed in the zoning and control strategy. The manifold is positioned for efficient routes and permanent service access.

Tile and stone transfer heat efficiently, while engineered timber, LVT, laminate, carpet and underlay each introduce their own thermal and temperature limits. Product approval, adhesive, moisture, curing, levelling and expansion details all belong in the design.
Water circuits are filled, vented and pressure-tested before concealment. During commissioning, circuits are balanced, control sequences are proved and the completed floor response is checked before handover.
Each layer is reviewed before it closes the next one in—from the structural floor and insulation to pipework, controls and final finish.
Postcode, plans, rooms, proposed finishes and project stage.
Floor build-ups, heat source, routes, access and electrical provision.
Room demand, active floor area, temperatures and zones.
Defined systems, preparation, components, controls and interfaces.
Substrate, insulation, levels and property protection.
Pipework or cable, manifold, actuators, thermostats and wiring.
Pressure or electrical tests before the floor is completed.
Balancing, functional proof, operating information and handover.
A heat-loss assessment establishes whether the usable heated floor can meet the room requirement and whether another emitter is needed.
Usually the stronger option for living areas, whole floors and multi-zone systems integrated with a boiler or heat pump.
Practical for isolated bathrooms, en suites and tiled spaces where extending a water system would add disproportionate disruption.
Wet heating in principal rooms and electric floor warming in selected bathrooms can work together when each has a defined duty.
Underfloor heating crosses several trade boundaries. The heat design affects the floor build-up. The manifold needs plumbing routes and joinery space. Thermostats, actuators and wiring centres require electrical planning. The heat source must respond correctly to zone demand.
PEP brings those interfaces into one scope. Heating and Gas Safe work, fixed electrical work through our NICEIC discipline, plumbing, controls, testing and commissioning follow one coordinated programme.
With London experience since 2010, we understand that successful work in occupied and carefully finished Maida Vale properties depends on preparation, sequencing and protection as much as the equipment below the floor.
We cover Maida Vale and nearby areas where they form part of the same project or practical service route.
Floor construction, heat loss, final finish and the wider building determine the most sensible route.
It can be. Floor construction, available build-up, insulation, heat loss, lease conditions and acoustic requirements must be assessed before the system is selected.
The panel is only one part of the total build-up. Preparation, levelling, decoupling, adhesive and the chosen finish all affect the final level.
Wet systems usually suit larger areas and principal rooms; electric systems can suit isolated bathrooms and compact tiled spaces. The decision depends on duty, area and construction.
Yes, provided the flooring product is approved for UFH and its thermal resistance, temperature limit, moisture and installation requirements are included in the design.
Sometimes. We review the boiler, system arrangement, calculated demand, temperatures and controls before confirming compatibility.
Yes, where the property heat loss, active floor area and design temperatures support the intended heat-pump operation.
Yes. A multi-zone system can use room thermostats, actuators and a wiring centre, subject to the agreed control strategy and heat-source interface.
Leasehold conditions vary. Alterations affecting floors, structure, acoustic layers or communal arrangements may require approval before disruptive work begins.
Cost depends on area, construction, preparation, zones, controls and heat-source integration. PEP provides a project-specific quotation for the defined scope.
Send the W9 postcode, plans if available, room dimensions, known floor construction, intended finishes, heat-source details and the current project stage.
Send the W9 postcode, available drawings, floor information and intended finishes. We will review the construction, system options and practical next step.